fbpx ...
English

Parallel Groove Clamp

Parallel Groove Clamp

Short Description: Energy-saving torque clamp is the non-load-bearing connection fittings,mainly used in transmission lines, distribution lines and substation line system, splicing and play a lead role in jumpers. Applicable to aluminium wire,copper wire,overhead insulated wire, ACSR wire,etc., but also for copper wire pair copper wire, aluminum wire to aluminum wire, copper wire to aluminum conductors such transition.

Overview

Energy-saving torque clamp is the non-load-bearing connection  fittings,mainly used in transmission lines, distribution lines and substation line system, splicing and play a lead role in jumpers.

Applicable to aluminium wire,copper wire,overhead insulated wire, ACSR wire,etc., but also for copper wire pair copper wire, aluminum wire to aluminum wire, copper wire to aluminum conductors such transition.

Feature

1.No limit to voltage grade, capable of reusing.
2.With highly corrosion resistance aluminum alloy, the clamp and the bolt has the good mental elasticity, which forming the energy reserve system with the connecting conductor . Greatly improved the overload capacity and the service life of the clamp.
3.The span design of the clamp can do with different kind of branch line and main line connecting.
4.Special torque nuts can keep constant contact pressure between wire and clamp for a long time and ensure the best installation and good electrical connection of each clip.
5.Trunking clamp the wire in each contact are coated with a conductive unique antioxidants,increased a conductor contact surface ,and effectively block the air and the water, to prevent the contact wire and clamp surface due to oxidation or other corrosion caused less contact.
6.Convenient construction, can be installed perfectly without the special tool, never influence by human factor.,

JBY Instructions for ordering and the technical parameters

Type Cablerange Dimension Bol t Qty. Insulated Shield
L B H R M
JBY-302 10-95 46 52.5 55 8 8 2 JBY-302(Z)
JBY-502 25-150 50 52.5 55 8 8 2 JBY-502(Z)
JBY-602 50-240 82 66 70 11.5 12 2 JBY-602(Z)
JBY-603 50-240 122 66 70 11.5 12 3 JBY-603-803(Z)
JBY-803 95-300 133 66 70 11.5 12 3 JBY-603-803(Z)

PGA Instructions for ordering and the technical parameters

Type Cablerange Dimension Bolt Qty. Insu la ted Shie ld
L B H R M
PGA-302 10-95 45 40 55 6.5 8 2 PGA-302(Z)
PGA-502 25-150 56 49.5 55 8 10 2 PGA-502(Z)
PGA-602 50-240 56 62 70 10 10 2 PGA-602(Z)
PGA-603 50-240 86 62 70 10 10 3 PGA-603-803(Z)
PGA-803 95-300 120 75 80 13 12 3 PGA-603-803(Z)

Installation Guide  

1. Unpack and check if the product model is matching with the conductor wire, to install  it after making sure it’s all correct.

2. Clean up the oil stain and Oxidation Film on the surface of the conductor,  until the surface gloss to paint the conductive pipe. (Peel off the conductor if it has the insulation)

3. Loosen the torque nut till the conduct wire can be insert to the sides of the clamp

4. Insert the wire in parallel to the clamp slot

2
3
Copyright © 2023 Maxun Power Technology Co., LTD. All Rights Reserved.

LEAVE A MESSAGE

Contact us!
We're not around but we still want to hear from you! Leave us a note:

* indicates a required field