fbpx ...
English

Insulated Piercing Connectors

10kV Insulation Piercing Connector With Grounding Rings

Short Description: High Voltage 10kV two bolts Insulation Piercing Connector with Grounding rings for Earthing Protection Description 10kv two bolts insulation piercing connector with Earthing Ring for Earthing Protection and Temporary Electrical Inspection.It is suitable for majority types of ABC conductors as well as connections to service and lighting cable cores. When tightening the bolts, the teeth of the contact plates penetrate the insulation and establish a perfect contact. The bolts are tightened until the heads shear off. Tightening torque guaranteed(fuse nut). Stripping of insulation is avoided. Service condition: 400/600V, 50/60Hz, -10°C to 55°C Standard: IEC 61284, EN 50483, IRAM2435, NFC33 020. Suitable for Aluminum and copper conductors

Overview

10kv two bolts insulation piercing connector with Earthing Ring for Earthing Protection and Temporary Electrical Inspection.It is suitable for majority types of  ABC conductors as well as connections to service and lighting cable cores. When tightening the bolts, the teeth of the contact plates penetrate the insulation and establish a perfect contact. The bolts are tightened until the heads shear off. Tightening torque guaranteed(fuse nut). Stripping of insulation is avoided.

Service condition: 400/600V, 50/60Hz, -10°C to 55°C

Standard: IEC 61284, EN 50483, IRAM2435, NFC33 020.

Suitable for Aluminum and copper conductors

Features

• Tested for watertightness at a voltage of 6 kV for 30 min in a waterbath
• Potential free tightening bolts allow safe installations on life lines
• Bimetallic, suitable for aluminium and copper conductors
• Long neck 13 mm shear head nut ensuring reliable installations
• Components not losable, end cap attached to body
• Insulation material made of weather and UV resistant glass fibre reinforced polymer

1kV piercing grounding clamp selection table

It is suitable for 1kV overhead insulated conductor grounding protection and temporary electrical inspection.

model Equivalent model Applicable voltage Applicable wire Main dimensions (mm) Nominal current Number of bolts Puncture depth
(kV) (mm²) A B H (A) (Pieces) (mm)
WXF1-95/16 JJCD1-16-95 1 16-95 120 103 80 214 1 3-4
WXF1-120/35 JJCD1-35-120 1 35-120 120 103 80 316 2 3-4
WXF1-150/50 JJCD1-50-150 1 50-150 120 103 80 316 1 3-4
WXF1-185/95 JJCD1-95-185 1 95-185 125 103 110 276 1 3-4
WXF1-240/150 JJCD1-150-240 1 150-240 125 103 110 276 1 3-4

10kV puncture grounding clamp selection table

It is suitable for 10kV overhead insulated conductor grounding protection and temporary electrical inspection.

model Equivalent model Applicable voltage Applicable wire Main dimensions (mm) Nominal current Number of bolts Puncture depth
(kV) (mm²) A B H (A) (Pieces) (mm)
WXF10-95/25 小型 10 25-95 154 120 110 276 1 3-4
WXF10-95/25 JJCD10-95-25 10 25-95 144.5 140 92.5 257 2 4-5
WXF10-120/35 JJCD10-120-35 10 35-120 148 120 86 316 2 4-5
WXF10-185/95 JJCD10-95-185 10 95-185 152 140 112.5 476 2 4-5
WXF10-240/150 JJCD10-150-240 10 150-240 160 140 1125 476 2 4-5

10kV distribution line grounding clamp

Suitable for 10kV distribution line grounding protection

model Equivalent model Applicable voltage Applicable wire Main dimensions (mm) Nominal current Number of bolts Puncture depth
(kV) (mm²) A B H (A) (Pieces) (mm)
WXF10-95/25(Match) Small(Match) 10 25-95 148 138 86 316 1 3-4
WXF10-95/25(Match) JJCD10-95-25(Match) 10 25-95 148.5 140 98 257 2 4-5
WXF10-120/35(Match) JJCD10-120-35(Match) 10 35-120 154 138 110 276 2 4-5
WXF10-185/95(Match) JJCD10-95-185(Match) 10 95-185 152 140 113 476 2 4-5
WXF10-240/150(Match) JJCD10-150-240(Match) 10 150-240 160 140 113 476 2 4-5